2016年11月27日星期日

CX Turbine flow meter

Turbine Flow meter


Porter:sales9@gnflowmeter.com
Site:www.microflowmeter.com

        
               

This manual contains the standard technique specification, model, installation, operation and maintainment of CX-LTFM turbine flowmeter. Please read the manual before using the meter. But there are neither different features of different users nor technique specification of every time or structure because some amendments will not affect the function and operation of the meter.
Model CX-LTFM turbine flowmeter adapts to measure the liquid rate and total flowrate of low viscosity. It can be widely used in the fields of Petrol, Chemical industry, Metallurgy, Scientific research for measuring or control.
Several output and display methods can be selected (detailed in the table of model code).
The executed standard number of the product isZB N12 005-1989

Parameters:
Nominal Diameter
DN(mm)
Range(m3/h)
Liquid Temperature
(℃)
Nominal Pressure
PN(MPa)
Ambient Temp.
(℃)
Max. Pressure Loss
(MPa)
Error  
0.2%*
Error    0.5%
Error      1%
Min.
Max.
Min.
Max.
Min.
Max.
2*




0.03
0.16
-20
 to
+120
6.3
-25
to
+55
0.15
4*




0.04
0.25
0.12
6


0.1
0.6
0.1
0.6
6.3
16
25
32*
0.08
10


0.25
1.2
0.2
1.2
0.05
15
1.2
6
0.6
4
0.6
6
0.035
25
2
10
1.6
10
1
10
40
4
20
3
20
2
20
1.6
2.5
0.025
50
6
40
4
40
4
40
80
16
100
10
100
10
100
100
25
160
20
160
20
200
1.6
2.5
150
50
300
40
300
40
400
200
150
750
100
600
80
800
250*
200
1000
160
1000
120
1200
1.6
300*


260
1600
180
1800

没有评论: