  Designed in three-wire or two-wire system, E Series Display Circuit is a newly emerged compact circuit of Vortex Flow Meter. Its amplified circuit belongs to the Analog type. Within the conventional flow range, the flow rate of gas, liquid and steam can be measured in high accuracy through using this E Series Display Circuit. In addition, switches can be set up to adapt to a variety of medium-calibers and various kinds of measurements. Remote data processing and remote signal circuit are divided into three-wire system and two- wire system. The three-wire system can be connected with RS485 communication equipment; it is also battery-powered. Using 4-20mA current output, the two-wire system can provide isolated original pulse output.

1. Main Technical Parameters
1.1 Applicable Caliber: DN15-DN300, other caliber agreement supply.
Applicable medium: gas, steam and liquid.
1.2 Environmental conditions:
Ambient temperature: (-30 ~ +70) / (-20 ~ +60 liquid-crystal display).
Relative humidity: 5% ~ 90% Atmospheric Pressure: (86 ~ 106) kPa.
Medium temperature: (-50 ~ +250) , (-50 ~ +350) .
1.3 Power Supply
 a. Three-wire System
(1)    When using external power supply: 12 ~ 24VDC/30mA (-20% ~ +15%), no output can be as low as 9V
(2)    When battery-powered (optional): Lithium battery 3.6V (2-13Ah) / 0.3mA.
     b) Two-wire system   12~24VDC/4-20mA(-20%~+15%)
1.4 Output Signal
a) Three-wire system
(1)    Pulse output: High level ≥ 8V (power supply voltage -1V).
Low Level <0.5V.
2    With 1K5 pull-up resistor open collector output
3    RS485 communication: The meter can be configured to RS485 communication interface. Communication range ≤ 1200mm.
b) two-wire system
(1) Second-line 4 ~ 20mA linear correction electronic current output (When the voltage is 24V, the circuit load ≤ 600Ω).
(2) No amendment to the original pulse optical isolator output: high ≥ 5V (power supply voltage of-1V).
(3) Low <0.5V; with 1K5 pull-up resistor open collector output. Extra 12V electronic power need to be supplied.

Parameters
L
H
Flange
Bolts
OD of flange
Hole distance of bolts
hole diameter of bolts
q'ty
size
15
180
415
95
65
14
8
M12x60
20
180
420
105
75
14
8
M12x60
25
180
425
115
85
18
8
M16x60
32
180
435
140
100
18
8
M16x70
40
180
435
150
110
18
8
M16x70
50
180
440
165
125
18
8
M16x70
65
180
460
185
145
18
8
M16x70
80
200
490
200
160
18
16
M16x70
100
220
510
220
180
18
16
M16x70
125
240
535
250
210
18
16
M16x70
150
270
570
285
240
22
16
M16x70
200
300
625
340
295
22
24
M16x70
250
320
685
405
355
26
24
M16x70
300
350
710
460
410
26
24
M16x70
350
375
790
520
470
26
32
M16x70
400
400
845
580
525
30
32
M16x70